INSTALLATION INSTRUCTIONS
9
Exhaust Hose Installation
The exhaust hose and adaptor must be installed or removed
in accordance with the usage mode:
COOL mode = install
FAN / DRY mode = remove
1. Attach both adaptors A and B to the exhaust hose. Extend
each end of the hose by couple inches and turn the adaptor
as shown in Fig 14. Do not over-tighten. Refer to previous
page for window kit installation.
2. Align Adaptor A to the air outlet opening and push
along the arrow direction as in Fig 15.
Through-the-Wall Installation
The exhaust hose can be installed through the wall.
It is necessary to purchase the following parts:
Wall Adaptor
(sold separately, please contact
Sunpentown at 1-800-330-0388
or visit www.spt-usa.com)
Screws and expansion plugs
(can be purchased at any hardware
store)
1. Prepare a hole in the wall and install the Wall Adaptor to
the opening (from outside). Secure with 4 expansion plugs
and screws. Fig.16.
2. Attached exhaust hose to the Wall Adaptor.
Cover the hole using the adaptor cap when not in use.
IMPORTANT:
DO NOT OVER BEND THE EXHAUST HOSE
The exhaust hose can be compressed or extended moderately
according to the installation requirement, but it is desirable to
keep the hose length to a minimum.
CAUTION:
Make sure there are no obstacles blocking the air outlet of the
exhaust hose (in the range of 20 inches), for the exhaust
system to work properly.
OPERATING INSTRUCTIONS - CONTROL PANEL
Before you begin, thoroughly familiarize yourself with the control panel and remote controller
and all its functions, then follow the symbol for the functions you desire.
Note: Some of the units functions can only be controlled by the remote controller.
ELECTRONIC CONTROL - OPERATING INSTRUCTIONS
OPERATION PANEL OF THE AIR CONDITIONER
Selects the appropriate operating mode. Each
press of the button will select mode in the
following sequence: COOL, FAN and DRY. The
corresponding mode indicator will illuminate.
NOTE: Fan speed cannot be changed or set on
speed). Fan speed can only be set or changed by
the remote controller for COOL and FAN modes.
UP ( + ) and DOWN ( - ) button
22
11
MODE select button
Power switch, press to turn on/off.
ON-OFF button
44
Displays set temperature under COOL mode.
Displays room temperature under DRY and
FAN modes.
LED Display
E2- Evaporator temperature sensor error-
Unplug the unit and plug it back in.
If error repeats, call for service.
E4- Display panel communication error-
Unplug the unit and plug it back in.
If error repeats, call for service.
Error codes:
E1- Room temperature sensor error.
Unplug the unit and plug it back in.
If error repeats, call for service.
Protection codes:
P1- Bottom tray is full - connect drain hose
to the drain outlet to empty the bottom tray.
If code repeats, call for service.
Used to increase or decrease temperature setting
in 1°C or 1°F increments.
Adjustable range: 62°F to 86°F (17°C to 30°C)
NOTE: The control is capable of displaying
temperature in Fahrenheit or Celsius. To convert
from one to the other, press and hold the UP
and Down buttons simultaneously for 3 seconds.
Fig.18
11
22
33
33
44
22
Power indicator
light
Timer indicator light
(set only by remote controller)
the control panel (unit will operate under auto-fan
Fig.14
Fig.15
Fig.16
Fig.17